Backplanes with a different number of slots are, however, available as an option. FPE043UX160: 3U x 160mm x 4HP: VME, 1101. 5-2003 VME2eSST Specification, ANSI/VITA 1. 7 mmVME64x Backplane, 6 U, 3 Slot With P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. Open VPX is the architecture framework that defines system level VPX interoperability for multi-vendor, multi-module, integrated system environments. 1 Intended Application The VME64x system subrack, described in this manual, is intended as a platform for a microcomputer system based on the VME64x bus system (VITA 1. 1 Gigabit Ethernet VME64x backplane, VITA 38 IPMB to all slots, 2 fabric slots, 19 node slots XXXX Notes: 1. 1-1997, VME extension standard. (1) VME320 is a patented backplane construction by Arizona Digital, Inc. 1-1997 VITA 38 systems management for VME At the right side is a connector for the power supply, at the left side a connector for the Fan Tray. We provide all standard features required for VME64x compatibility, including 160-pin VME extension connectors in J1 and J2, all defined ground pins connected to a ground plane, routing and termination of all. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. Item Description. High-speed backplane operation is a direct result of the improved OEC circuitry and high drive that has been designed and tested into the VME64x backplane model. VME64 - VME64x (VERSAmodule Eurocard) P1. The Elma Electronic VME64x backplane series is designed to fully comply with the ANSI/VITA VME extension standard. 4 optical, 67. Our VME Backplanes are made for industrial applications in different form factors, including vertical and horizontal orientation of the backplane and cards. J2 Monolithic) conforms to: VITA 1. VME64x versions in 12- and 16-slots; 21 slots for -HP version. 8 VMEbus basics • Electrical properties – All lines use TTL levels – Low = 0. : 73972-077 • Benutzeranleitung Power-BusplatineVME64x Backplanes Fremont, Calif. System Slot: Slot 1 Left. 1, November 14, 2008 1 Safety 1. Pixus has a virtually unlimited array of configuration options for 19" rackmount VPX Eurocard-based enclosures and a wide selection of rugged/ATR system. Excellent power and ground distributionMechanical specifications . 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEBackplane VME-J1. High-Quality Backplane Solutions for VME and VME64x Applications. Includes termination passive inboard, daisy chain automatic active, and power bugs on top and bottom of slots. Add to Cart. nVent SCHROFF offers: VMEbus and VME64x systems available for 6U boardsare “C” (6U x 340mm) and “D” (9U x 340mm) and the backplane pitch is 1. 23001-546 VME64X BACKPLANE, 6 U, 16 SLOT WITH P0 KEY FEATURES In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. 7-2003 (R2009) increased current level for VME (96 pin) and VME64x (160 pin) DIN/IEC connectors. Item Description. 7 Increased Current. M. Processor PMC (ANSI/VITA 32) - Incorporates a set of extensions to the PMC standard, which creates a new class of Processor PMC cards. Track Finder Crate, Backplane and Parts. Open VPX is the architecture framework that defines system level VPX interoperability for multi-vendor, multi-module, integrated system environments. • User Manual VME64x Backplanes Order no. 1) and 2eSST protocols in VITA 1. 6U VME64x Backplane 15-slot with P0, compliant with ANSI/VITA 1. S33-1U Rugged Commerical. 7 Increased Current. 1, and V67. 1 Intended Application The VME system subrack, described in this manual, is intended as a platform for a microcomputer system based on the VME bus system (VME (VITA 1-1994) and VME64x (VITA 1. 1-1997 VME64x; ANSI / VITA 1. Read More7U VME64x Backplane 7-slot w/o P0, compliant with ANSI/VITA 1. Item/Part Number. 5-2003 VME2eSST Specification, ANSI/VITA 1. 6U VME64x Backplane 10-slot with P0, compliant with ANSI/VITA 1. Versions for VITA 66 and VITA 67 available. 5-2003 VME2eSST Specification, ANSI/VITA 1. 3 volts) and ground (GND) on P1 and 'User Defined' signals on P2; (VME64x P2 Connector Pin Outs). This plane provides all the address, data and control lines, and is fully capable of operating as a standalone bus. Unobstructed. Backplane connector is Harting 02-02-160-2201 female type. The extra 1U provides room for extra power bugs or busbars. Fits any Eurocard packaging standard based card cage as it meets the form factor and mounting provisions called out in the VITA Specification. S33-1U Rugged Commerical. S34-HP VME64X. VITA 38-2003 (S2022), System Management on VME. bus is based on J1-only version of the VME64x backplane, which utilizes 160-pin 5-row connectors. 1-1997 VME64 Extension Standard, ANSI/VITA 1. 3 volts) and ground (GND) on P1 Pinout and 'User Defined' signals on P2. VME64 and VME64x (optional) comes with an enhanced connector. 1-1997, VME extension, and VITA 1. Where modules provide support for it, we encourage the use of geographical addressing as this will simplify your. Test adapter allows measurement and testing of both 3 and 6U assemblies (CompactPCI, VME64x) Test adapter can be mounted in chassis with an overall depth of up to 220 mm. • Backplane: With J0 Connector. : 73972-103 • Short Form User Manual VME64x Backplanes Order no. 09 mm, thickness of 1. M. Specifications • High-performance, low noise, very high powerBACKPLANES VME64X - 6U FEATURES • Automatic active Daisy Chain • Configured for „normal range“ power supply • Power input: M3/M4 power bolts M3/M4 cable lugs, • washer and nuts enclosed • 10-layer construction • Passive inboard termination (basic current consumption • 1. The B-portI/Os are optimized for driving large capacitive loads and include pseudo-ETL input thresholds (½ VCC ± 50 mV) for increased noise immunity. 1-1997, VME extension standard Exceeds ANSI/VITA 1-1994 and IEEE P1014 specifications 10-layer. VME64X 6U 5 Slot with P0. Backplane Configuration: 7 Slot. ANSI / VITA conform portfolio of VME and VME64x backplanes: Up to 21 Slots; 3 U and 6 U rack height; ANSI / VITA 1-1994 VME64; ANSI / VITA 1. 6U VME64x Backplane 9-slot with P0, compliant with ANSI/VITA 1. VPX can offer compatibility through the use of hybrid backplanes with VME/VME64x slots. HD63 - VME64x backplane rear shroud (160 positions shroud) HD64 - VME backplane rear shroud (96 positions shroud) RoHS Status: Lead free / RoHS CompliantVME / VME64x Backplanes. 6" d P2 and P0 backplane backside connector pins required Minimum 2. This platform conforms to VITA 1. 5-2003 VME2eSST Specification, ANSI/VITA 1. 1, with Type I Ejector handles. Backplane options include either 12 or 16 slots, with P0 connectors and auto-jumpering. S34 Commerical. Find the right VME or VME64x system for your application, available with horizontal or vertical card cages, as subrack or desktop versions, pluggable or open frame power supplies and included cooling concept: VMEbus and VME64x systems available for 6U boards. Available with up to 21 slots. The B-port I/Os are optimized for driving large capacitive loads and include pseudo-ETL input thresholds (½ V CC ± 50 mV) for increased noise immunity. Rows "A", "B", and "C" remain unchanged. The backplane trace impedance can vary between 45 Ω and 60 Ω, the stub impedance is about 60 Ω, and the connector impedance is about 67 Ω. VXI Backplanes. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEThe VME64x backplane forms the basis for the VITA31. 1-1997 VME64x; ANSI / VITA 1. VME64x 5-row connector backplanes with 160 pin enhanced connector. 3 VME64x Backplane The horizontally assembled 6 U backplane (J1. 6U VME64x Backplane 8-slot with P0, compliant with ANSI/VITA 1. Includes termination passive inboard and daisy chain automatic active. Includes termination passive inboard, daisy chain automatic active, and power bugs on top and bottom of slots. backplanes) BG0 BG3 BG2 BG1 IACK 6U VME64x backplane. x) adds a high-speed MultiGig connector over P0 of a VME64x backplane for serial data traffic. At this time, all of the backplanes in use in NSCL experimental setups support the CERN style geographical addressing extensions. Refined VPX connector with smaller press-fit pins, the VITA 46 Multigig RT-3 is. 1 and 1101. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VME Table of Contents, Abstract and Foreword Do not specify or claim conformance to this draft standard VME64x, VITA 1. Available with up to 21 slots. com, a global distributor of electronics components. VME and VME64x Systems. Check part details, parametric & specs updated 29 OCT 2023 and download pdf datasheet from datasheets. Item Description. The retry cycle prevents deadlock (deadlystandard VME64x cards and backplanes, but it does not mate to other types of VME commercial connectors. 6U VME64x Backplane 21-slot with P0, compliant with ANSI/VITA 1. Some systems have obstructions such as power supplies behind J1 which prevents direct insertion of RTM’s. 7U VME64x Backplane 18-slot with P0, compliant with ANSI/VITA 1. 101V64XC05-0621R. Backplanes with a different number of slots are, however, available as an option. Item Description. This platform conforms to VITA 1. FAQs; Novastar (3D) Configurator. : 73972-103 • Short Form Manual VME64x 6U Backplanes Bestellnr. VME 64x 6U 166 Series. The VME64x system subracks are designed for protection class. VME64x Backplanes From Pixus Feature Various Power Options. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VME specified on VME and VME64 backplanes (both 96-pin and 160-pin). 5-2003 VME2eSST Specification, ANSI/VITA 1. VME64x Backplane. It was added to the 160 pin P1/J1 connector in the VME64x specification. 3-997. (For OpenVPX products, see the Pixus OpenVPX section. 3 + 5 V + 1 2 -1 2 F A N T E M 10006841 VME64x Backplane Fan Tray Front card cage Rear card cage Air filter Power Supply Fan Control Module (FCM) Page 10: SubrackHot swap (in conjunction with VME64x backplane) VME64x Connectors. General Backplane Specification for VME and VME64x Slot Count : 2-21 slot options Size : “True” 6U, 10. Where these charges should be7U VME64x Backplane 2-slot with P0, compliant with ANSI/VITA 1. VME64x Side Shielding. Each of these styles of backplanes are available in 3U and 6U form factors. Part Number Listed on Mainframe: 14V05OPX38N4HCZ0. Includes termination passive inboard and daisy chain automatic active. • User Manual. Includes termination passive inboard and daisy chain automatic active. 5-2003 VMVME64x System Subrack 10 U Safety 20836-220 3 R1. 7U VME64x Backplane 3-slot w/o P0, compliant with ANSI/VITA 1. Backplane Configuration: 5-Slot. The most rugged packaging for computing. 1-1997, is an extension of the VME64 standard ANSIVITA 1-1994. Hartmann Electronic’s slimmest 19” rack mountable VME solution – The VME64x 1U system. It is designed as a 8-layer board in strip-line technology. 5 4 3 2 1 0 –1 100 120 140 160. schroff. Backplanes. The busses have active on. It was added to the 160 pin P1/J1 connector in the VME64x specification. VME J1/J2 & VME64x J1/J2/P0, Monolithic 6U Backplanes, 2 to 21-Slot VME64x 160-pin Vectorbord® Backplanes VME & VME64x Backplanes VMEBP07P00 Rear View VME64E21P01 Front View Ohm Resistance of signal lines. Hartmann Electronic is an industry leader in the designing, manufacturing and production of backplane technology, including VME and VME64x. • Drive Bay: None Installed. This VME chassis comes with two 300W cPCI hot-swap power supplies with room for up to 4 supplies and horizontally oriented card slots. VME / VME64x Technical Data Mechanical and Climatic Parameters VME Backplanes VME64x Backplanes Operating Temperature -25°C - +85°C (active termination) -40°C - +85°C (passive termination) -40°C - +105°C (on request) Storage Temperature -40°C - +105°C -55°C - +105°C (on request) Humidity 95%, non condensingVME64x Backplane, 6 U, 8 Slot Without P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. : 73972-103 • Short Form Manual VME64x 6U Backplanes Bestellnr. 6UX160MM horizontal card cage; 3-slot, P1P0P2 VME64x. The 6U “classic” VME64x backplane features power bugs above and below the slots to maximize space. Part Number: 11-1011777-2119. Includes termination passive inboard and daisy chain automatic active. 1 Intended Application The VME64x system subrack, described in this manual, is intended as a platform for a microcomputer system based on the VME64x bus system (VITA 1. Amphenol supplies an adapter interconnect system for “cocooning” of COTS VME64x daughtercards. VME64x Backplane, 6 U, 5 Slot With P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. VXI Backplanes. VME64x backplanes must not bus or terminate this signal. The Hartmann Power Backplanes are rugged, reliable and powerful. Product Features 19" rackmount 9U enclosure, pre-galvinized sheet steel with attractive finish. An optional advanced system monitor provides status of all power supply outputs, fan speeds, and VME64x Backplane, 6 U, 11 Slot Without P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. 5-2003 VME2eSST, VME64 and VME64x; ANSI / VITA 1. The VME64x backplane supports 19” rack applications. 1-1997 VME64 Extension Standard, ANSI/VITA 1. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEVME64x. 1-1997, VME extension, and VITA 1. Move to confirm Mr. 1 May 04, 2009 Technical data fans updated Impressum: Schroff GmbH D-75334 Straubenhardt, Germany The details in this manual have been carefully compiled and checked - supported by. pdf VME64x Backplane, 6 U, 8 Slot With P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. The various headers are basically the same, except the 12-pin friction lock for +/- V1 and V2 has only 8 pins (one less pin per type). Compare this product Remove from comparison tool. 7 Increased Current. The busses have active on board termination and active automatic daisy-chain (CBLT compatible!). Front View Comtel VME64x Backplanes ANSI/VITA 1. VXS (VITA 41. VME / VME64x Backplanes. VXS adds additional high-speed serial data transfer up to 10 Gbps to the backplane and supports both Single and Dual Star topologies. Includes termination passive inboard and daisy chain automatic active. 6U VME64x Backplane 11-slot without P0, compliant with ANSI/VITA 1. It defines a keying system that can be added to VME64x boards and backplanes in a conduction cooled environment (IEEE 1101. Backplane Type: VME64x with EDC. Page 1 VXS/VME64x Tower System User’s Manual Product No. 94-1. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEAdditional Information. VME64x Backplane, 6 U, 15 Slot Without P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. The 6U monolithic WIENER J1/J2 backplane fully complies with ANSI/VITA 1-1994 and IEEE-1014-1987 specifications. Vector offers a VMEbus and VME64x J1 only backplanes currently in 21, 16, 15, 10 and 9 slots per ANSI/VITA 1. Further information can be found in the user manual of the backplane: Order-User Manual VME / VME64x Backplanes 73972-103 Rev. Extended Description. : 73972-077 • Benutzeranleitung Power-BusplatineThis Elma 21-Slot VME Chassis is used and in excellent condition. VME64x Backplane, 6 U, 10 Slot Without P0. cPCI Serial Backplanes. 3M™ MetPak™ HSHM Connector used in a VME64x backplane 2. The B-port I/Os are optimized for driving large capacitive loads and include pseudo-ETL input thresholds (½ V CC ± 50 mV) for increased noise immunity. 1-1997 VME64 Extension Standard, ANSI/VITA 1. The extra 1U provides room for extra power bugs or busbars. 1-1997 VME64 Extension Standard, ANSI/VITA 1. Further information can be found in the user manual of the backplane:An extension to that standard called VME64x also supports geographical addressing, in a different way. It defines 9U x 400 mm boards, backplanes and subracks for use in application requiring large format printed circuit boards. The Elma Electronic 6U VME64x Backplane 5-slot with P0, compliant with ANSI/VITA 1. Extended Description. Depending on local conditions, packaging and freight charges might not be included. Technical Specifications Backplane Compatibility: ANSI/VITA 1-1997 VME Extensions standards; PICMG 2. 7 Increased Current. All VME64x systems require a minimum of level 2 performance. The 6U monolithic WIENER J1/J2 backplane fully complies with the VME64 Extensions specification according to ANSI/VITA 1. User Guide VME64x 6U Backplanes 23001 - 5xx Assembly Instructions Warning: It's important only if V1 and V2 are used If the +V1 and +V2 voltage rails are tied to ground and the +12V power is used, the nominal voltage between the +12V and the -V1 and -V2 power rails is 60 volts. 1-1997 VITA 38 systems management for VME The system is supplied with a 8 slot backplane. Hartmann Electronic’s 4 slot 19” rack mountable VME solution – The VME64x 2U system. 1-5 slots. VME64x Backplanes. Our serial backplane technology comes equipped with either single star or serial full mesh topology for the highest quality backplane on the market. 16-Slot 6U OpenVPX Gen3 Backplane. : 73972-128 Die Benutzeranleitungen können im Internet bei heruntergeladen werden. 7-2003 Increased Current LeVME64x Backplanes. 1-1997, VME extension, and VITA 1. Hartmann Electronic is THE Expert in backplane technology. There are three general types of backplanes available: Standard, 3-row connector backplanes. : 73972-091 • User Manual Fan Control Module (FCM) Order no. KEY FEATURES : Backplane Specification : ANSI / VITA 1. It was added to the 160 pin P1/J1 connector in the VME64x specification. 1-1997 VME64 Extension Standard, ANSI/VITA 1. Backplane VME64x J1/J0/J2. 10/. Our experience of backplane design, manufacturing, development and electrical test technologies allows us to6U VME64x Monolithic; 6U VME Monolithic; ACCESSORIES. VXI Backplanes. It is designed as a 10-layer board in strip-line technology. 1-1997 VME extension standard and ANSI/VITA 1-1994, the VME64x line features a controlled-impedance stripline design. connector. All VME / VME64x Backplanes 0 of 0 results All Elma Electronic VME backplanes are designed to maximize performance, minimize noise, and to give the customer the most reliable, cost-effective product possible. Machen Sie sich vor101VMEJ212-0900. It defines: VME and VME64x Systems. VME / VME64x Backplanes J1 Backplane: The basic configuration is the 3U high (Single Eurocard) J1 plane. 1-1997, VME extension, and VITA 1. 1 backplane. VME J1/J2 & VME64x J1/J2/P0, Monolithic 6U Backplanes, 2 to 21-Slot VME64x 160-pin Vectorbord® Backplanes VME & VME64x Backplanes VMEBP07P00 Rear View VME64E21P01 Front View Ohm Resistance of signal lines <1. The Elma / Bustronic 7U VME64x Backplanes are designed to fully comply with the ANSI/VITA VME extension standard. 6U VME64x Backplane 8-slot with P0, compliant with ANSI/VITA 1. Depending on local conditions, packaging and freight charges might not be included. The VME64 five row connector pinout is listed on either the VME64x P1 Pinout page or VME64x P2 Pinout page. Includes termination passive inboard, daisy chain automatic active, and power bugs on top and bottom of slots. All VME / VME64x Backplanes 0 of 0 results All. Amphenol supplies an adapter interconnect system for “cocooning” of COTS VME64x daughtercards. 5-2003 VME2eSST Specification, ANSI/VITA 1. • User Manual VME64x Backplanes Bestellnr. This standard is an extension of the ANSI/VITA 1-1994, VME64 Standard. 0. 1-1997, VME extension standard. The backplanes also employ the company's "DawnWrap" metallization technology which reduces EMI/RFI emissions and system noise. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. Connector Type: DIN 41612, VME64x Power Connector Type: Power Bugs for M4 Cable Lugs. : 73972-083 • Benutzeranleitung Netzteil Bestellnr. 10/11 as well as IEC 60297-3-101, -102, -103. Includes termination passive inboard and daisy chain automatic active. Subrack based, sheet metal, desktop or tower configurations. With voltage tolerances, the 60 volt maximum is exceeded. A suspicious death, an upscale spiritual retreat, and a quartet of suspects with a motive for murder. Dual backplane bridges are user configurable. backplane. Discreet 3U high VME64 and VME64x backplanes are fully RoHS compliant and perform to ANSI/VITA 1. 100")] @ IEEE 1014-1987; [VME] P1 and P2 are 160 pin DIN (41612, Type C. 8" pitch). 5 Gbps through Tx+RX connectors100 I/O points from backplane to two 50-pin SCSI-2 con-nectors at the rear of the card cage. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEPage 7: References And Architecture Specifications. 5-2003 VME2eSST Specification, ANSI/VITA 1. 3V RT2211 Standard VME64 +5V RT2210 Low Voltage Termination VME64x +3. 2 options. Schroff VME64x backplanes fulfil the requirements of the VME Live Insertion standard VITA 3. Up to 36,864 channels from a focal plane with 24×24 SiPM 64 pixel arrays can be handled by a 8-slot VME64X crate, in which 6 slots will be dedicated to Level 2 trigger boards, 1 slot for. Product Information. Includes termination passive inboard and daisy chain automatic active. ELMA Electronic, Inc. 2. Includes termination passive inboard, daisy chain automatic active, and power bugs on top and bottom of slots. 7-2003 Increased Current Level; ANSI / VITA 3-1995 Live Insertion System; ANSI / VITA 38-2003 System Management; Discover more 1 Backplane VME for 6: U boards, 5 slots, J1/J2 monolithic (part no. Item/Part Number. pdf; OpenVPX-Backplane-SOSA-VITA66-VITA67-6U. 1-1997 VME64 Extension Standard, ANSI/VITA 1. 6-10 slots passive active. The VME64x extension, which is downwards compatible, allows higher data transfer rates and added rear I/O boards to VME. 6U VME64x backplane. 3V RT2211 Standard VME64 +5V RT2210 Low Voltage Termination VME64x +3. : 73972-103 • Short Form User Manual VME64x Backplanes Order no. Machen Sie sich vor♦ Choice of 4-slot VME64x backplane or 4-slot CompactPCI ™ PICMG 2. The 27bit trigger number (134M count) is not a limitation, as it will be used to distinguish events within event. 5-2003 VME2eSST Specification, ANSI/VITA 1. 5-2003 VMVME / VME64x Backplanes. Highly competitive customization available. SMT Line The Elma Bustronic SMT line is over 40’ long and includes an in-line printer, a pick-and-place SMT assembly machine, re-flow. The B-port I/Os are optimized for driving large capacitive loads and include pseudo-ETL input thresholds (½ V CC ±50 mV) for increased noise immunity. We provide all standard features required for VME64x compatibility, including 160-pin VME extension connectors in J1 and J2, all defined ground pins connected to a ground plane, routing and termination of all. VXS In 2004, the VITA 41 architecture was created. Monolithic 6U high VME64 and VME64x backplanes are fully RoHS compliant and perform to ANSI/VITA 1. The retry cycle prevents deadlock (deadly. Hartmann Electronic is an industry leader in the designing, manufacturing and production of backplane technology, including VME and VME64x. VME Scaler. ANSI/VITA 1. 1-1997 VME64 Extension Standard, ANSI/VITA 1. Part Number: 11-1011777-2119. Primarily these additions are power (+3. ELMA Electronic, Inc. Backplane Part Number: 101VE64XM05-0621. 7 Increased Current. 3-Slot 3U OpenVPX/ ComapctPCI cPCI Backplane. 1-1997, VME extension standard. May 8, 2012. P47, 4U. 7-2003 (R2009) increased current level for VME (96 pin) and VME64x (160 pin) DIN/IEC connectors. 1 May 04, 2009. VXS (VITA 41. Hartmann Electronic is an industry leader in the. Includes termination passive inboard, daisy chain automatic active, and power bugs on top and bottom of slots. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VMEThe Dawn VME DEV-7713 VME64x Tabletop Development Chassis is ideal for use in office and laboratory environments. The backplane is actively terminated. This manual provides detailed information on the features, specifications, wiring and troubleshooting of the backplanes. 7 Increased Current. The SN74VMEH22501A is pin-for-pincapatible to the SN74VMEH22501 (TI literature number SCES357), but operates at a wider operating temperature (−40°C to 85°C) range. 3 Power Backplane A Power Backplane (23098-115) is located to the right of the VME64x Backplane providing two P47 connectors to connect to 3 U / 250 W plug-in power supplies. 3 volts) and ground (GND) on P1 and 'User Defined' on P2 (next page). 73972-103, in the catalogue or on the internet at 2. VME64x backplane 23001-032. Hartmann Electronic is an industry leader in the designing, manufacturing and production of. 5 inches preferred)VME64x System Subrack 4 U Safety 20836-416 1 R1. IP 54/55 dürfen die. Page 9: Vme64X Backplane Order-No. : 73972-103 • Short Form Manual VME64x 6U Backplanes Bestellnr. B. Power Connector Type: Power Bugs for M4 Cable Lugs. Highly competitive customization available. ) on DirectIndustry, the industry specialist for your professional purchases. VPX–0650 25Gbps SOSA 14. 7-2003 (R2009) increased current level for VME (96 pin) and VME64x (160 pin) DIN/IEC connectors. Excellent signal integrity at 2. We are a key VITA Technologies contributor member for the definition and development of OpenVPX™ and SOSA™ standards. The extra 1U provides room for extra power bugs or busbars. *The price shown is the per piece price and does not include VAT. VME64x versions in 12- and 16-slots; 21 slots for -HP version. 7 compliant VME64x 21-slot backplane with J0 connectors (VX21) = RACEway certified VME64x 21-slot backplane with J0 connectors (V021) = VME 21-slot backplane (VP21) = VITA 31. VME64X 6U 15 Slot with P0. Speeds up to 100GbE. Part Number: 012-983, 32220-209-0B60. Amphenol’s Ruggedized VME64x rectangular connectors were developed with the military’s need for rugged connector solutions and the trend toward utilizing COTS (Commercial Off the Shelf) boards, backplanes or chassis. VXS (VITA 41. PCB connector is Harting 02-01-160-2101 male right. are not included with this equipment unless listed. 8. 7 Increased Current. VME64x Backplane, 6 U, 3 Slot With P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. 7U Vme64x BACKPLANES - Elma Electronic. VME64x backplanes must not bus or terminate this signal. Primary additions are power (+3. 1-1997 VME64 Extension Standard, ANSI/VITA 1. The VMEbus signals can go across the MultiGig high-speed connectors to the legacy VME/64x slots. 7-2003 Increased Current Level; ANSI / VITA 3-1995 Live Insertion System; ANSI / VITA 38-2003 System ManagementVME64x Backplane, 6 U, 4 Slot Without P0 In accordance with ANSI/VITA 1-1994 VME64 Standard, ANSI/VITA 1. Chassis – Turnkey, Fully Assembled and Tested, Convection, Conduction and Liquid Cooling. 101V64XM18-0620R. 1-1997. B. Over the evolution of its near 40 years of existence, VME-bus has become a worldwide standard and is still used in a wide variety of applications across many different markets. VME64x 2U/84HP 4 Slots. 7-2003 Increased Current Level, ANSI/VITA 38 System Management on VME VME-VME64 6U 162 Series. Joos – Introduction to VMEbus 10 VMEbus basics • Classes of modules (logical) – Master This backplane allows for plug-in of both Legacy or VME64x boards and VPX boards into the same backplane. The Kontron CP6930 hot-swappable CPCI switch serves 24 GbE ports to the backplane or rear transition modules and six high capacity SFP+ 10GbE links at the front for high speed inter- and intra-connects plus 2 SFP 1 Gb ports. Vector uses ERNI P0 connectors. The same style of connector is also used for switch slots, driving the centralized fabric signals.